image
image

image

 


IVF Clean Air100C Air Filtration Purification100C Air FiltrationFilter AirOur StaffSearch Filtration SiteContact Air FiltrationAir Filtration Home PageZander IVF

 

ZAND-AIR™ 100P
Air Purification Systems

Photo-Catalytic Air Purification for Biochemistry & Pathology Laboratories

image

"As technology has advanced, the necessity to filter air has become even more important"  

No matter how well you maintain your laboratory, your work area can be filled with air pollutants, dust particles, mold spores, dander, pollen, dust mites, cleaning chemicals, volatile organic compounds (VOCs), chemically active compounds (CACs), aldehydes, carcinogenic materials, carbon monoxide, viruses and bacteria.

  Air Purification Filtration System  
 
ZAND-AIR™ 100P
 
Add to these culprits the chemical irritants lurking about… in carpets from the front office, behind walls, from off-gassing in plastic materials, in the cleansers and waxes used to keep your laboratories and work surfaces clean.  All these can have a direct influence on your results and on the health of laboratory workers.

The key to effective air filtration of damaging volatile air compounds is in the Photo-Catalytic-Oxidation - the chemical compounds become highly reactive when exposed to a specific wavelength of ultraviolet light.  The photo-catalyst attracts pollutants and converts them into benign compounds such as water (H20) and carbon dioxide (C02).

The ZAND-AIR 100P Air Purification System  significantly reduces:

 
  • Bacteria & Viruses
  • Mold
  • Fungus
  • Cleaning Chemicals
  • Paint
  • Solvents
  • Ozone & Smog
  • Nitrous Oxide
  • Hair Spray
  • Perfume
  • Pesticides
  • Alcohols
  • Ammonia
  • Chlorinated Solvents
  • Carbon Monoxide

Over 50 other chemicals were decomposed significantly with the ZAND-AIR™ 100P  Air Purification System

  Air purification system  
 
ZAND-AIR™ 100P
AIR PURIFICATION SYSTEM
 

STEP ONE:

Activated Carbon Filter adsorbs toxic chemicals and gases

The FRONT POSITION Activated Carbon Filter, a specially formulated mixture of proprietary compounds selected to adsorb all VOCs and CACs in the laboratory environment. Scientifically formulated adsorption media (including zeolite and potassium permanganate) adsorbs automobile exhaust fumes, organic hydrocarbons, formaldehyde used in the laboratory and from particle boards used in construction, paints, solvents, chlorine, cleaning chemicals, volatile organic compounds (VOCs), chemically active compounds (CACs) and other harmful and carcinogenic agents.

STEP TWO:

Higher adsorption of VOCs and CACs

A second Activated Carbon Filter increases the ‘dwell time’ providing a higher adsorption of VOCs and CACs.

STEP THREE:

Photo-Catalytic Oxidation destroys toxic chemicals and eliminates odors from the air

Photo-Catalytic-Oxidation converts toxic compounds (even carbon monoxide and nitrous oxide) into benign constituents such as C02 and H20. The catalyst is such that it does not wear out or lose its effectiveness as a result of its actions.

STEP FOUR:

Ultraviolet Light

The UV light with the photocatalyst attacks pollutants and coverts them into benign compounds such as water (H2O) and carbon dioxide (CO2). Ultraviolet technology combined with Photo-Catalytic-Oxidation is an important feature of this air purification system since germs are easily spread from person to person and by central heating and air-conditioning systems.


Electronic Sensors

Electronic sensors monitor air quality and automatically increase the performance of the air purification system to compensate for periods of unusually high chemical activity,  and increased human activity. Air Purification Control

Warning lights alert staff to the presence of toxic chemicals and fumes well before they reach dangerous levels or become detectable to the human senses. In the absence of high activity, the air purification system can switch into a sleep mode and "wakes up" as soon as it detects activity.

 

Photo-Catalytic purification cleans air down to the last molecule

The key to Photo-Catalytic-Oxidation is the titanium dioxide in the photo-catalytic chamber*, where it becomes highly reactive when exposed to a specific wavelength of ultraviolet light.  In the presence of organic pollutants, such as solvents, hydrocarbons, alcohols, carbon monoxide, dyes, and fuel oils, the activated photo-catalyst attacks the chemical bonds of the pollutants, converting the toxic compounds into benign constituents such as H2O and CO2 .

The UV lamp used in the ZAND-AIR100P  Air Purification System has an output in the 254-nanometer wavelength range.  This wavelength destroys bacteria and viruses and does NOT produce ozone.

Ozone is not detected in any measurable quantity at the exit grill of an operating ZAND-AIR™ 100P.

UV light is not reflected by most surfaces but absorbed and thus cannot exit through the outlet grill of the ZAND-AIR100P Air Purification System.  The “blue” visible light seen when the unit is operating is characteristic for the UVC lamp, and is not an indication of UV radiation emission.

Important Summary Features of the ZAND-AIR™ 100P
Air Purification System

  • Air Purification is effective up to 2,000 square feet / 185m2 and it only costs a few cents a day to operate full time, 24 hours a day.

  • Model ZAND-AIR 100P Air Purification System has two activated carbon filters which significantly increases the dwell time as air passes across the filters.  The combination of the two filters traps solvents, VOCs and CACs, acids such as hydrogen sulphide, sulphuric acid, hydrogen chloride, formaldehyde and other aldehydes.

  • Designed for biochemical and pathology laboratories, the ZAND-AIR100P  will play a major part in protecting laboratory staff from harmful agents such as zylene, toluene, benzene, and other carcinogenic agents.

  • Electronic Sensors monitor air quality and automatically increase or decrease the performance of the air purification system.

ZAND-AIR™ 100P   Air Purification System Description

  • AIR OUTLET GRILL WITH SAFETY LOCK
  • AIR INLET GRILL WITH SAFETY LOCK
  • HIGH OUTPUT U.V. LAMP DESTROYS GERMS
  • PHOTO-CATALYTIC OXIDIZER
  • HIGH EFFICIENCY, LOW NOISE, REVERSED CURVED, MOTORIZED IMPELLER WITH SEALED BALL BEARINGS
  • HIGH IMPACT ABS PLASTIC WITH NO OFF-GASSING
  • ACTIVATED CARBON FILTER
  • COMPUTERIZED ELECTRONIC CONTROLS
  • INFRARED MOTION DETECTOR
  • TOXIC CHEMICAL SENSOR TO MONITOR AIR QUALITY
ZAND-AIR™ 100P   Air Purification System Technical Specifications
  • Dimensions: 21.5"w X 18"h X 8"d (55cm X 46cm X 20cm)
  • Weight: 23 Ibs. (10.43 kg)
  • Max Air Flow: 265 cfm /7.5 m3 per minute
  • Max Watts: 110 watts
  • Voltage: 120v - 60hz /220v - 50hz
  • Blower: Reversed - curved motorized impeller
  • Catalyst: Metal oxides
  • U.V. Range: 254 nm (produces no ozone)
  • Gas Absorption: Two stage activated carbon media
  • Application: 2,000 sq. feet max. (185 sq. meters)
  • Service: U.V. Lamps -1 year, Filters - 6 months
  • Warranty: 2 year limited warranty on all components excluding light and filters

Additional Links

 

Air Filters

 

*Operational validation tested and verified by: Truesdale Laboratories, Inc., Southwest Research Institute, and Aire Limpio S.L

image


Zander Air Filters

Site by WebInnovations.org



 

 